Contractors

NC8 AC Contactor
Waterproof Box (Plastic Screw)
General Information
The NC8 series AC contactor is used for remote making & breaking circuits, and can also be used with proper thermal overload relay together as an electromagnetic starter to
protect circuits from overload. Rating up to 690V, 500A, AC 50/60Hz
Standard: IEC/EN 60947-4-1 Utilization category: AC-1, AC-3, AC-4 Mounting

NC7 AC Contactor
Waterproof Box (Plastic Screw)
General Information
The NC7 series AC contactor is mainly used for remotely closing and breaking circuits,
and can be combined with an appropriate thermal overload relay to form a
electromagnetic starter so as to protect the circuits likely to be overloaded in operation; the contact is well suited for frequently starting and co

NC6 Contactor
Waterproof Box (Plastic Screw)
General Information
● The NC6 Series Mini Contactor is used in remote motor (≤4kW) control application.
● Rating up to 690V, 9A (AC-3). —– (06A, 09A)
● Standard: IEC/EN 60947-4-1
● Two kinds of mounting available: Normal type (without pins); Pin type (with pins)
● Ambient temp: -5℃~+40℃
● Coil voltage (AC): 24V, 36V, 48V, 110V, 127V, 220V, 230V, 380V, 400V;

NC1 Contactor
Waterproof Box (Plastic Screw)
General Information
● The NC1 Series Contactor is used in remote motor (≤45kW) control application.
● Rating up to 690V, 95A (AC-3). —– (09A, 12A, 18A, 25A, 32A, 40A, 50A, 65A, 80A, 95A)
● Standard: IEC/EN 60947-4-1
● Ambient temp:-25℃~+55℃
● Coil voltage (AC): 24V, 36V, 48V, 110V, 127V, 220V, 230V, 380V, 415V, 440V, 480V, 500V, 600V, 660V

NC1-Z(N) DP Contactor
Waterproof Box (Plastic Screw)
General Information
Rated working voltage up to 690V, 25A and 40A (AC-3)
w/ 2 NO 2 NC main contacts
Compliance standards: IEC / EN 60947-4-1
Ambient air temperature: -25℃~+55℃,
24-hour average temperature not exceeding +35℃
Altitude: ≤ 2000m
Coil voltage: DC 48V

NC2 Contactor
Waterproof Box (Plastic Screw)
General Information
● The NC2 Series Contactor is used in remote motor (≤475kW) control application.
● Rating up to 690V, 800A (AC3). (115A,150A,185A,225A,265A,330A,400A,500A,630A,800A)
● Standard: IEC/EN 60947-4-1
● Ambient temp: -5℃~+40℃
● Coil voltage (AC): 110V, 127V, 220V, 230V, 380V, 400V;

NCK3 DP Contactor
Waterproof Box (Plastic Screw)
General Information
● The NCK3 Series DP Contactor is used in remote motor
of air-conditioner (<60HP) control application.
● Rating up to 630V, 90A. —– (25A, 30A, 32A, 40A, 50A, 60A, 75A, 90A)
● Standard: UL508
● Poles: 1P+1NC, 1P+N, 2P, 3P
● Ambient temp: -5℃~+40℃
NCK3 ● Coil voltage (AC): 24V, 110V,120V, 220V,240V (50/60Hz)

NCH8 Modular AC Contactor
Waterproof Box (Plastic Screw)
General Information
● For controlling the household device or similar low inductive electric device
● Manufactured according to IEC/EN 61095
● Utilization categor y: AC-1, AC-7a, AC-7b
● Electric ratings: up to 20A, 25A, 40A, 63A, 230V, 400V, AC50/60Hz;
● Various contact assembly are available

CJ19 Capacitor Switching Contactor
Waterproof Box (Plastic Screw)
General Information
● The CJ19 Series Contactor is used in remote capacitor (130kvar) switch application.
● Rating up to 400V, 130A (AC-6b). —– (25A, 32A, 43A, 63A, 95A,115A,150A,170A)
● Standard: IEC/EN 60947-4-1
● Ambient temp: -5℃~+40℃
● Coil voltage (AC): 24V, 36V, 48V, 110V, 127V, 220V, 230V, 380V
Relay

NR8 Thermal Overload Relay
Waterproof Box (Plastic Screw)
General Information
● Standard: NR8 series thermal overload relay is used to provide overload
and phase failure protection for AC motors
● Frequency: AC 50Hz/60Hz
● Voltage: up to 690V
● current: 0.1A~38A
● IEC 60947-4-1.

NRE8 Electronic Overload Relay
Waterproof Box (Plastic Screw)
General Information
The NRE8 Series Electronic Overload Relay is used
in remote motor control application for overload function.
● Rating up to 690V, 630A (AC3). —– (25A, 40A, 100A, 200A, 630A)
● Standard: IEC/EN 60947-4-1
● Ambient temp: -5℃~+40℃
● Assemble with Contactor NC1, NC2, NC7,NC8 to be a DOL Starter

NR2 Thermal Overload Relay
Waterproof Box (Plastic Screw)
General Information
NR2 series thermal overload relay is used to provide overload and phase failure
protection for AC motors.
● Rating up to 690V, 630A. —– (11.5A, 25A, 36A, 93A, 150A, 200A, 630A)
● Standard: IEC/EN 60947-4-1
● Ambient temp: -5℃~+40℃
● Assemble with Contactor NC1, NC2, NC7 to be a DOL Starter.
starters

NS2 Manual Motor Starter
Waterproof Box (Plastic Screw)
General Information
● The NS2 Series Manual Motor Starter is used in remote motor control application
for overload, short circuit & phase failure.
● Rating up to 690V, 80A(AC3). —– (0.1~0.16A, 0.16~0.25A, 0.25~0.4A,
0.4~0.63A, 0.63~1A, 1~1.6A, 1.6~2.5A, 2.5~4A, 4~6.3A, 6~10A,
9~14A, 13~18A, 17~23A, 20~25A, 24~32A,
16~25A, 25~40A, 40~63A, 56~80A)

NQ2 Direct On-line Motor Starter
Waterproof Box (Plastic Screw)
General Information
● The NQ2 Series DOL Motor Starter is used in remote motor (≤33kW)
start & control application.
● Rating up to 660V, 68A (AC3).—– (0.1~0.16A,0.16~0.25A,0.25~0.4A,0.4~0.63A,
0.63~1A,1~1.6A,1.25~2A,1.6~2.5A,2.5~4A,4~6A,5.5~8A,7~10A,9~13A,12~18A,
17~25A,23~32A,28~36A,30~40A,37~50A,48~65A,55~70A,63~80A)

NQ3 DOL Electromagnetic Starter
Waterproof Box (Plastic Screw)
General Information
● The NQ3 Series DOL Motor Starter is used in remote motor (≤11kW)
start & control application.
● Rating up to 660V, 22A (AC3). —– (0.1~0.16A,0.16~0.25A,0.25~0.4A,0.4~0.63A,
0.63~1A,1~1.6A,1.25~2A,1.6~2.5A,2.5~4A,4~6A,5.5~8A,7~10A,9~13A,12~18A,
17~25A)
● Standard: IEC/EN 60947-4-1
● Ambient temp: -5℃~+40℃

NQB1 Series Protection Starter
Waterproof Box (Plastic Screw)
General Information
● The NQB1 Series Motor Starter is used in remote motor (≤7.5kW) control & protection application.
● Rating up to 690V/18A (AC-3): 0.1~0.16A, 0.16~0.25A, 0.25~0.4A, 0.4~0.63A, 0.63~1A, 1~1.6A,
1.6~2.5A, 2.5~4A, 4~6.3A, 6~10A, 9~14A, 13~18A
● Standard: IEC60947-4-1
● Ambient temperature: -5℃~+40℃
● Coil voltage (AC): 110V, 220, 380V