Fuse Protector

NRZ28-20 Fuses for Protecting Solar Photovoltaic System

Fuse Protector

General Information
● Standards compliant: GB / T 13539.6, IEC60269-6
● Rated voltage not exceeding DC1000V
● Rated current not exceeding 20A
● Rated short-circuit capacity not exceeding 20kA
● Breaking range and use category: gPV type
● CQC,TUV,CE and other domestic and international certification have been obtained.

CRT36-00 DC Fuse Protector

Fuse Protector

General Information
● Standards compliant: GB 13539.1, GB / T 13539.4
● Rated voltage: to DC80V
● Rated current range: 2A ~ 600A complete current specifications
● Rated breaking capacity: 25kA
● Breaking range and use category: gS type
● RX1 signal fuses can be equipped with to achieve remote function.
● Fuses special for communications industry have obtained CCC certificate and TUV certification

NRT36 Knife Contact Fuse Protector

Fuse Protector

General Information
● Standards compliant: GB / T 13539.2,IEC60269
● Rated voltage: to AC690V
● Rated current range: 2A ~ 160A complete current specifications
● Rated breaking capacity: 120kA
● Breaking range and use category: gG type
● RX1 signal fuses can be equipped with to achieve remote function.
● Fuses special for communications industry have obtained CCC certificate and TUV certification

NRT28 Cylindrical Contact Caps Fuse Holder

Fuse Protector

General Information

● Standards compliant: IEC60269-2
● Rated voltage: 500V
● Rated current range: 32~125A
● Mainly used for electrical circuit overload and short circuit protection
● NRT28 series holder can be used with RT28-32、RT28-63、RT29-125 ”gG” type fuse

RT28 Cylindrical Contact Caps Fuse Protector

Fuse Protector

General Information

● Standards compliant: GB / T 13539, IEC60269
● Rated voltage: to AC500V
● Rated current range: 32A ~ 63A
● Rated breaking capacity: 50kA
● Breaking range and use category: gG type
● Support member of the fuse can be equipped with lamp (X), and the instruction is more clear
● Patented appearance,modular design, practical and good-looking

RT29 Fuse with Cylindrical Cap

Fuse Protector

General Information

● Standards compliant: GB / T 13539.2, IEC 60269-2
● Rated voltage: AC500V
● Rated current range: 2A ~ 125A complete current specifications
● Rated breaking capacity: 50kA
● Breaking range and use category: gG type
● Fuse link of the impactor is equipped with, and it has the phase loss protection function as
the motor.

RT36 Knife Contact Fuse Protector

Fuse Protector

General Information

● Standards compliant: GB / T 13539.2,IEC60269-2
● Rated voltage: to AC690V
● Rated current range: 4A ~ 1250A complete current specifications
● Rated breaking capacity: up to 120kA safer
● Breaking range and use category: gG type
● Open structure,good heat dissipation condition
● Self design, use more confident with CHINT special models

Terminal Blocks

SAK Terminal Blocks

Terminal Blocks

General Information

● Standards compliant: GB/T 14048.7, IEC 60947-7-1
● Rated working voltage: AC 690V,DC 440V
● 2 2 Rated cross-sectional area: 2.5mm ~70mm
● 10 pieces of conventional terminal are assembled into 1 strip
● TH35-type guide rail can be used for installation

JXB Terminal Blocks

Terminal Blocks

General Information

● Standards compliant: GB/T 14048.7, IEC 60947-7-1
● Rated working voltage: AC 690V,DC 440V
● 2 2 Rated cross-sectional area: 2.5mm ~70mm
● 10 pieces of conventional terminal are assembled into 1 strip
● TH35-type guide rail can be used for installation

JCUK Terminal Blocks

Terminal Blocks

General Information

● Standards compliant: GB/T 14048.7, IEC 60947-7-1
● Rated working voltage: AC 690V,DC 440V
● 2 2 Rated cross-sectional area: 2.5mm ~150mm
● Built-in wiring mode, with finger protection function
● Use the high strength engineering plastic, safe and environmental protection
● TH35-type guide rail can be used for installation

TB Terminal Blocks

Terminal Blocks

General Information

● Standards compliant: GB/T 14048.7, IEC 60947-7-1
● Rated working voltage: AC 600V
● Rated working current: 15A-100A
● Conventional terminals become strips separately
● Screws are used for fixed installation

TC Terminal Blocks

Terminal Blocks

General Information

● Standards compliant: GB/T 14048.7, IEC 60947-7-1
● Rated working voltage: AC 600V
● Rated working current: 60A-600A
● Conventional terminals become strips separately
● Screws are used for fixed installation

TH35-7.5(C45) Rail

Terminal Blocks

General Information

DC Contactor, Change-over Switch,Combination Switch

CZ0 DC Contactor

DC Contactor, Change-over Switch,Combination Switch

General Information

● Standards compliant: GB 14048.4, IEC 60947-4-1
● Use category: DC-1,DC-3,DC-5
● Rated voltage: DC 220V
● Rated current: DC-1,DC-3,DC-5
40A,100A,150A,250A,400A,600A
● Good dynamic stability and thermal stability
● For remote making and breaking the DC circuit,can control DC motor starting

LW32 Universal Change-over Switch

DC Contactor, Change-over Switch,Combination Switch

General Information

● Standards compliant: GB 14048.5, IEC 60947-5-1
● Use category: AC-15,DC-13
● Rated voltage: AC-15,AC 380V
DC-13,DC 220V
● Rated current: AC-15 2.6A,DC-13 0.27A
4
● Mechanical life: 60 × 10
● 4 Electrical life: AC-15,20×10

HZ10 Combination Switch

DC Contactor, Change-over Switch,Combination Switch

General Information

● Standards compliant: GB 14048.3, IEC 60947-3
● Use category: AC-22A AC-3 DC-21A
● Rated voltage: AC-22A AC-3 380V DC-21A 220V
● Rated current: AC-22A 10A,25A,60A,100A
DC-21A 10A,25A,60A,100A
● 4 Mechanical life: 2 × 10
● 3 Electrical life: 5×10

YBLX-ME Travel Switch

DC Contactor, Change-over Switch,Combination Switch

General Information

● Standards compliant: GB 14048.5, IEC 60947-5-1
● Use category: AC-15 DC-13
● Rated voltage: AC-15 380V DC-13 220V
● Rated current: AC-15 0.8A DC-13 0.16A
● Conventional thermal current:5A
● 4 Mechanical life: 60 × 10
● 4 Electrical life: 30×10
● Compact size,quick action, diverse operating methods

YBLX-WL Travel Switch

DC Contactor, Change-over Switch,Combination Switch

General Information

● Standards compliant: GB 14048.5, IEC 60947-5-1
● Use category: AC-15 DC-13
● Rated voltage: AC-15 380V DC-13 220V
● Rated current: AC-15 0.79A DC-13 0.15A
● Conventional thermal current:5A
● Mechanical life: 60 × 10⁴
● Electrical life: 30×10⁴
● A variety of operating and installation methods meet the requirements of various occasions

YBLX-P1 Travel Switch

DC Contactor, Change-over Switch,Combination Switch

General Information

● Standards compliant: GB 14048.5, IEC 60947-5-1
● Use category: AC-15 DC-13
● Protection level: IP52
● Rated working voltage: AC 380V DC220V
● Rated control current: AC 0.8A DC 0.16A
● Mechanical life: 60 × 10⁴
● Electrical life: 30×10⁴
● Conventional thermal current: 5A

YBLX-K1 Travel Switch

DC Contactor, Change-over Switch,Combination Switch

General Information

● Standards compliant: GB 14048.5, IEC 60947-5-1
● Use category: AC-15 DC-13
● Protection level: IP52
● Rated working voltage: AC 380V DC220V
● Rated control current: AC 0.8A DC 0.16A
● Mechanical life: 60 × 10⁴
● Electrical life: 30×10⁴
● Conventional thermal current: 5A

YBLX-K3 Travel Switch

DC Contactor, Change-over Switch,Combination Switch

General Information

● Standards compliant: GB 14048.5, IEC 60947-5-1
● Use category: AC-15 DC-13
● Protection level: IP52
● Rated working voltage: AC 380V DC220V
● Rated control current: AC 0.8A DC 0.16A
● Mechanical life: 60 × 10⁴
● Electrical life: 30×10⁴
● Conventional thermal current: 5A

YBLX-10 Travel Switch

DC Contactor, Change-over Switch,Combination Switch

General Information

● Standards compliant: GB 14048.5, IEC 60947-5-1
● Use category: AC-15 DC-13
● Protection level: IP52
● Rated working voltage: AC 380V DC220V
● Rated control current: AC 0.8A DC 0.16A
● Mechanical life: 60 × 10⁴
● Electrical life: 30×10⁴
● Conventional thermal current: 5A

YBLX-19 Travel Switch

DC Contactor, Change-over Switch,Combination Switch

General Information

● Standards compliant: GB 14048.5, IEC 60947-5-1
● Use category: AC-15 DC-13
● Protection level: IP52
● Rated working voltage: AC 380V DC220V
● Rated control current: AC 0.8A DC 0.16A
● Mechanical life: 60 × 10⁴
● Electrical life: 30×10⁴
● Conventional thermal current: 5A

YBLX-22 Travel Switch

DC Contactor, Change-over Switch,Combination Switch

General Information

● Standards compliant: GB 14048.5, IEC 60947-5-1
● Use category: AC-15 DC-13
● Protection level: IP52
● Rated working voltage: AC 380V DC220V
● Rated control current: AC 0.8A DC 0.16A
● Mechanical life: 60 × 10⁴
● Electrical life: 30×10⁴
● Conventional thermal current: 5A

YBLX-JW2 Travel Switch

DC Contactor, Change-over Switch,Combination Switch

General Information

● Standards compliant: GB 14048.5, IEC 60947-5-1
● Use category: AC-15 DC-13
● Rated voltage: AC-15 380V, DC-13 220V
● Rated current: AC-15 0.79A, DC-13 0.15A
● Conventional thermal current: 3A

YBLT-3, YBLT-4 Foot Switch

DC Contactor, Change-over Switch,Combination Switch

General Information

● Standards compliant: GB 14048.5, IEC 60947-5-1
● Use category: AC-15 DC-13
● Rated working voltage: AC 380V, DC 220V
● Rated control current: AC 0.79A, DC 0.14A
● Conventional thermal current: 3A

YBLT-EKW/5A/B Foot Switch

DC Contactor, Change-over Switch,Combination Switch

General Information

● Standards compliant: GB 14048.5, IEC 60947-5-1
● Use category: AC-15 DC-13
● Rated voltage: AC 380V DC 220V
● Rated current: AC 0.8A DC 0.16A
● Conventional thermal current: 5A

YBLT-FS/1 Foot Switch

DC Contactor, Change-over Switch,Combination Switch

General Information

● Standards compliant: GB 14048.5, IEC 60947-5-1
● Use category: AC-15 DC-13
● Rated voltage: AC 380V DC 220V
● Rated current: AC 0.79A DC 0.14A
● Conventional thermal current: 5A

YBLT-FS/201 Foot Switch

DC Contactor, Change-over Switch,Combination Switch

General Information

● Standards compliant: GB 14048.5, IEC 60947-5-1
● Use category: AC-15 DC-13
● Rated voltage: AC 380V DC 220V
● Rated current: AC 0.8A, DC 0.16A
● Conventional thermal current: 5A

YBLXW-5 Microswitch

DC Contactor, Change-over Switch,Combination Switch

General Information

● Standards compliant: GB 14048.5, IEC 60947-5-1
● Use category: AC-15 DC-13
● Rated voltage: AC 380V, DC 220V
● Rated current: AC 0.79A, DC 0.14A
● Protection level: IP52

YBLXW-6 Microswitch

DC Contactor, Change-over Switch,Combination Switch

General Information

● Standards compliant: GB 14048.5, IEC 60947-5-1
● Use category: AC-15 DC-13
● Rated voltage: AC 380V, DC 220V
● Rated current: AC 0.79A, DC 0.14A
● Protection level: IP52

● Operating frequency: 40 times / min

JD Electromagnetic Speed-adjustable Motor Controller

DC Contactor, Change-over Switch,Combination Switch

General Information

JD, JZT, ZLK, ZTK electromagnetic speed-adjustable motor controllers are products designed jointly (uniformly) nationwide by the former Ministry of Machinery Industry and used for the speed control of electromagnetic speed-adjustable motor (slip motor) to achieve constant torque stepless speed regulation. This controller applies only to slip motor, not to general
motor.

Ask Assistant